Machine learning is good at finding apparent patterns but is poor at determining root causes. This can be problematic at times, especially when the data set used is small or involves bias based on what information is provided. Information about the shelf life of a group of drug products may not be predictive of the behavior of a different group. Making stability predictions with limited data sets requires an understanding of the fundamental mathematical and mechanistic factors involved including data generated on the specific drug product.

 

Patterns are not mechanisms

A machine-learning model learns statistical relationships between the data it is given and the outcomes in its training set. It has no built-in knowledge of chemistry or physics. It does not know that heat speeds up hydrolysis or that moisture can drive degradation in a solid dosage form. It only knows which inputs have tended to show up alongside which results. AI can link an excipient with slower degradation without knowing whether or how the excipient caused it. For example, depending on its level, the same excipient could cause some loss of drug crystallinity in a tablet (making it less stable) or absorb moisture in a particular package slowing an increase in tablet water activity during storage (stabilizing the drug). Scientifically designed experiments with statistic data fitting are important in not only rapidly determining drug product shelf life, but also in providing insight into how best to stabilize a drug product. Many data-driven machine-learning methods identify stability correlations, but provide limited insight, especially with the very limited data actually available.

 

Limits of machine learning for stability rates

Machine-learning approaches learn apparent patterns from available data to apply to other products. That only works if the new product behaves like the ones in the training data. In drug development, that is rarely a safe assumption. A drug product’s stability depends on many factors including some that are specifically captured (amenable to machine learning) and others that are important yet unable to be fed into the training information for machine learning. This causes two formulations that nominally appear similar to have very different stability behaviors. One example involves degradation rates for crystalline drugs formulated into solid dosage forms. The rate of degradation will be heavily dependent on what percentage of the drug is locked in a crystal lattice versus present in other forms, e.g., amorphous regions, solid-solutions with adjacent excipients, crystal defect sites, surface molecules. Since these important variables are not typically captured in data sets used to train machine learning, AI stability predictions based only on drug structure and excipient selections could be very far off from reality. While it is currently feasible to predict what types of degradation will occur given a molecular structure, rates of degradation are dependent on factors that are not easy to capture. The result is that studies (ideally scientifically designed) using the actual drug product are necessary to determine the shelf life of that product.

 

What regulators expect

Regulatory guidance reflects this uncertainty in general patterns for establishing drug product shelf life. ICH Q1E requires that a drug product’s shelf life be determined from the product’s own stability data, not on predictions based on apparent patterns. The new ICH draft guidance allows for accelerated stability modeling using such processes as ASAPprime®, but this work needs to be on the actual product.

 

Conclusion

At present, machine learning cannot, by itself, establish the shelf life of a new drug product. Any AI predictions must be shown to apply to that specific product. With very limited publicly available data, machine learning has very limited applicability in this field. Even when correlations are suggested by machine learning, there is a significant risk that a correlation would be mistaken for a causal relationship. There remains the need for well-designed scientific experiments to understand not only what degradation occurs, but how fast under particular storage conditions.


Sources consulted: Pfizer product labeling for Procardia XL (nifedipine extended-release tablets); The Pharmaceutical Journal, “Research and development in oral controlled release drug formulations”; DrugPatentWatch analysis of 505(b)(2) reformulation strategy and case examples (Concerta, Pennsaid 2%, Uceris, Colcrys).